5.6.2 Vacuum
1. Turn COOLIUS SELECT to set the vacuum time.
Minimum: 0 min.
Maximum: 999 min.
2. Press ENTER to conrm.
3. Turn COOLIUS SELECT to set the leak test time.
Minimum: 2 min.
Maximum: 60 min.
4. Press ENTER to conrm.
5.6.3 A/C system charge
A) In case of vacuum selected.
1. Turn COOLIUS SELECT to set the Fresh oil value.
NOTE: The value indicates only the new oil added to the
drained oil.
Minimum: 0 g.
Maximum: 150 g.
2. Press ENTER to conrm.
3. Turn COOLIUS SELECT to set the refrigerant amount.
Minimum: 50 g.
4. Press ENTER to conrm.
B) In case of vacuum not selected.
C) In case of A/C system charge.
5. Turn COOLIUS SELECT to set (usually HP).
HP-PORT” / “LP-PORT” / “HP/LP PORT”
6. Press ENTER to conrm.
7. Press START key to conrm.
The equipment performs all the process selected.
5.6.4 A/C pressure test
This procedure allows to check the A/C system (pressures) without recovering refrigerant from the system.
1. Press ENTER to conrm.
Vacuum time
min. 20
Leak test min. _
PAG Oil ml. 10
Refrigerant
g._____
Refrigerant
g._____
Charge A/C system by
HP PORT
A/C Pressure Test
