EasyManua.ls Logo

COOLIUS A10 - Report; Scale Reset

COOLIUS A10
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
COOLIUS A10
6.6 Report
The machine records the refrigerant usage monthly for the previous twelve months. Beyond this period, it will
overwrite the data for the month in question.
1. Turn COOLIUS SELECT to select the following coun-
ters:
REFRIGERANT RECOVERED FROM
A/C SYSTEM
REFRIGERANT RECOVERED FROM
EXTERNAL TANK
REFRIGERANT FILLED TO A/C SYSTEM
The display shows in sequence all the months and the total per year.
2. Press START to print the report.
6.7 Scale reset
At the purpose to compensate the scale deviation, perform the following instructions:
Locking the transportation lock.
1. Lift the knob on the back side of the machine, move it to the left and turn it in clockwise direction in order
to lock it into “safety position”.
2. Turn COOLIUS SELECT to select
SCALE RESET
3. Press ENTER to conrm.
4. Press START key to conrm the safety position
In case of mistake:
Perform again the procedure and be sure to follow
correctly the instructions!
5. At the end, bring back the knob to the “working position”
(turn it counter-clockwise, move it slightly up and to the
right, then fully down).
01/2017
R134a recovered
Kg. 10.0
Year 2017
R134a recovered
Kg. 210
Scale reset

Unload weight scale
(safety position)
ERROR!
Weight scale
A3

Table of Contents

Other manuals for COOLIUS A10

Related product manuals