Cold Nitro Brew BIB Dispenser Operator’s Manual
Publication Number: 621058723OPR ‐ 12 ‐ © 2017, Cornelius Inc.
4
Using a clean and empty food-grade container:
Prepare approximately 0.5 gallons (1.9 liters) of warm water.
Place container of water inside the cabinet storage area.
5
Place the BLACK product output connector with the WHITE
cleaning adapter inside the food‐grade container so that
the connector will stay at the bottom.
6
Turn the Sanitizing Valve to the “Dispense”
position and the Nitrogen valve to the “OFF” position.
7
A. Open LEFT tower dispenser and dispense 0.25 gallons (1
quart) of water or until the dispense looks clear.
B. Close the tap.
C. Open RIGHT tower dispenser and dispense 0.25 gal‐
lons (1 quart) of water or until the dispense looks clear.
D. Close the tap.
E. NOTE: DO NOT OPEN BOTH VALVES AT THE SAME TIME
AS DISPENSING MAY PULSE OR EVEN STOP.
8
Remove the bucket of water from the machine and dispose
of the remaining water.
Table 3.
Step Action