- 13 -
2. The unit has a built-in carbonator, connect the water line to the
pump.
Water Line Connected
to Pump
3. Connect optional drip tray drain hose (if used). Be sure the
knock-out in the drip pan has been removed if drain hose is
used.
4. If the unit has a built-in carbonator,
connect the CO2 lines. Be
sure the water and CO2 are on.
CO2 should be set at 75 psi
(5.25 bar) maximum. Higher CO2
pressure will result in LOWER
carbonation.
CO2 Inlet Carbonator
Bleed the air out of the carbonator (hold with wrench) Bleed Valve
by pulling up on the metal ring on
the bleed valve. Bleed each valve into a bucket until water comes out
for 2-3 seconds.