- 36 -
6. Install new motor by reversing this procedure.
CONTROLLER BOARD REPLACEMENT
1. Disconnect power to the unit.
2. Remove the following:
front merchandiser by removing screws on the top and lifting up
key switch wires
Screw on PCB cover
hood by removing screws on the top and lifting up and forward.
3. Push the cover off as arrow direction. Screw
4. Unplug all connectors.
5. Squeeze all four standoffs
and remove the board. Connector
in each Corner
6. Install new controller board by
reversing this procedure.
Water and CO2 to the system must be turned off and the system depressurized prior to performing
this service.
Failure to comply could result in serious injury,death or damage to the equipment.
WARNING
Disconnect power to the unit before servicing following all lock out\tag out procedures established
by the user.Verify all power is off to the unit before performing any work.
Failure to comply could result in serious injury,death or damage to the equipment.