- 22a -
Double Liquid Check Valve Inspection & Cleaning
CAUTION
The carbonator double-liquid check valve must be
at least once a year under normal conditions. If particles lodge in
the check valve CO2
and create a health hazard.
the check valve.
check the ball for damage. Replace damaged or suspicious parts.
3.
4. Reassemble and install the check valves.
5. Turn on the CO2
r.
Condenser Cleaning
Accumulation of dust and grease on the refrigeration condenser can
cause overheating. The condenser should be cleaned as often as
f
3. V
4. Clean around top of refrigeration assembly.
5. Reinstall merchandiser
1
2
1
2.
use low pressure compressed air.
Disconnect power to the unit before servicing following all lock out\tag out procedures established
by the user.Verify all power is off to the unit before performing any work.
Failure to comply could result in serious injury,death or damage to the equipment.
WARNING
Water and CO2 to the system must be turned off and the system depressurized prior to performing
this service.
Failure to comply could result in serious injury,death or damage to the equipment.
WARNING
CHECKING CARBONATED WATER TANK RELIEF VALVE (MONTHLY)
The relief valve on top of the carbonated water tank under the waterbath cover should be periodically
checked for proper operation by briefly pulling up on the relief valve ring.