COMPONENT SERVICE
The following are procedures for replacing the major components of the
Raja dispenser.
CARBONATOR PUMP REPLACEMENT
1. Disconnect power to the unit.
2. Shut off water and CO2 at their sources.
3. Remove the following:
• front merchandiser by removing screws on the top and lifting up
• key switch wires
• hood by removing screws on the top and lifting up and forward.
4. Depressurize carbonator by
removing the solenoid dust
cover from any dispensing Press Valve
valve and push down Solenoid to
on the solenoid. Depressurize
Pump Water
5. Disconnect water in and out lines. Connections
Water and CO2 to the system must be turned off and the system depressurized prior to performing
this service.
Failure to comply could result in serious injury,death or damage to the equipment.
WARNING
Disconnect power to the unit before servicing following all lock out\tag out procedures established
by the user.Verify all power is off to the unit before performing any work.
Failure to comply could result in serious injury,death or damage to the equipment.
WARNING