EasyManua.ls Logo

Cornelius Impulse XL - Condenser Fan Motor Replacement

Cornelius Impulse XL
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2010, IMI Cornelius Inc.
- 37 -
CONDENSER FAN MOTOR REPLACEMENT
1. Disconnect power to the unit.
2. Unplug motor harness.
Remove
3. Remove Four screws on Four Screws
mounting bracket.
4. Lift mounting bracket front tab out of
slot, then pull motor out from the
back.
5. Remove three screws holding motor
to bracket and remove motor.
3 Screws
6. Install new motor by reversing this
procedure.
Water and CO2 to the system must be turned off and the system depressurized prior to performing
this service.
Failure to comply could result in serious injury,death or damage to the equipment.
WARNING
Disconnect power to the unit before servicing following all lock out\tag out procedures established
by the user.Verify all power is off to the unit before performing any work.
Failure to comply could result in serious injury,death or damage to the equipment.
WARNING