- 29 -
TROUBLESHOOTING CARBONATOR
Trouble Probable Cause Remedy
Carbonator pump
not operating.
1. CO2 supply depleted.
2. Water supply to carbonator
disrupted.
3. Carbonated water tank water
level probe electrical wiring
disconnected.
4. Inoperative carbonated water
tank water level probe.
5. Inoperative carbonator pump
or motor.
6. Inoperative control board.
1. Replenish CO2 supply.
2. Correct water supply
problem.
LED Flashing = The
anti-!ood timer has expired,
the controller assumes a
tube or connector is broken.
Power to the carbonator
motor is shut off and the unit
needs to be shut down to
reset.
3. Connect electrical wiring to
water level probe (see note).
4. Replace probe (see note).
5. Replace pump or motor.
6. Replace control board.