14
CANADA ONLY
Be sure that the electrical connection and wire size are adequate and in
conformance with the CSA Standard C22.1, Canadian Electrical Code, Part 1 -
latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
ELECTRICAL CONNECTION
If
codes permit and a separate ground wire is used, it is recommended that a
qualified electrical installer determine that the ground path and wire gauge
are in accordance with local codes.
WA
RNING: Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualified electrician or service
technician if you are in doubt as to whether the appliance is properly
grounded.
To
properly install your appliance, you must determine the type of electrical
connection you will be using and follow the instructions provided for it here.
• Th
is appliance must be supplied with the proper voltage and frequency,
and connected to an individual, properly grounded branch circuit,
protected by a circuit breaker or fuse. See the rating plate located on the
oven frame to determine the rating of the product.
• Use
the table below to determine the minimum recommended dedicated
circuit protection.
Oven Type
Voltage,
Frequency
Power Rating
Recommended
Circuit
COS-30ESWC
Single Oven
240 V, 60 Hz
4,800 W
25 Amp
208 V, 60 Hz
3,605 W
20 Amp
COS-30EDWC
Double Oven
240 V, 60 Hz
8,500 W
40 Amp
208 V, 60 Hz
6,381 W
35 Amp