4-WIRE POWER SUPPLY CONNECTION
IMPORTANT: Use the 4-wire cable from power supply where local codes do
not permit connecting the oven ground conductor to the neutral (white)
junction box supply wire.
1. Remove junction box cover, if present.
2. Connect the flexible cable conduit from the oven to the junction box using
a UL listed or CSA approved conduit connector.
3. Tighten screws on conduit connector if present.
4. Using the UL listed wire connectors:
Connect the two black wires together.
Connect the two red wires together.
Connect the two neutral (white) wires together.
Connect the oven ground (green or bare) wire to the ground (green
or bare) wire in the junction box.
5. Install junction box cover.
4-Wire Cable from Power Supply
Oven Conduit
Black Wires
Ground (Green
or Bare) Wire
Red Wires
UL Listed or CSA
Approved Wire
Connector
Junction Box
White Wires