INSTALLATION MANUAL TECHNICAL SPECIFICATIONS 45
Electrical specifications
The Covana Evolution cover requires a dedicated single-phase 115 VAC (North America) or 220 VAC (Europe)
hard-wired power supply.
The Covana Evolution cover must be installed in accordance with and comply with all applicable local codes
and regulations. All wiring and connections should be performed by a qualified electrician.
Wires and conduits should be sized according to local codes and regulations.
North American requirements:
115 V, 60 Hz (1 hot, 1 neutral, 1 ground)
Class A 15 A single-pole GFCI (not included)
220 V, 50 Hz (1 hot, 1 neutral, 1 ground)
10 A single-pole GFCI (not included)
Operating limitations
WARNING:
The Covana cover should never be used if the following conditions are reached.
Gusts of 30 mph (50 km/h) while in the raised position
and upwards of 45 mph (70 km/h) when completely
closed on the hot tub.
Maximum weight on the cover (evenly distributed)