82
5.4.2.8 Commands
In the Command section it’s possible to access the following sub-menus:
Power On/Off
Force Restart
Factory Reset
Auto Test
MPPT Scan
CEI
“Power On/Off” menu: Manual Turn ON/OFF: Manual Power ON/OFF
is required after regulation setting or manual (fault) shut-down.
Force Restart
menu: If a fault shutdown happens, a severe fault may
have occurred inside the inverter. The user can perform a force reboot for one
time per Power on in this menu if the user needs to restart the inverter.
“Factory Reset
menu: The manufacturer’s parameter default values can
be restored when the inverter is not in operation mode. Otherwise “Fault
Operated” will be reported.