Product Manual Doc. 9324A IV-SAM-VXP-1B and IV-SAM-VXS-1B 25
If using multiple devices, a P300, Q-SYS, SCM-820, or Tesira device (or the Intellimix Room
software) must be set as an adjudicator. To set an adjudicator device, select the Enable
Adjudicator check box, then enter the control IPaddress of the device into the Adjudicator IPtext
field.
Microphone Device Settings Table - Enable Adjudicator
Select the device model from the Adjudicator Model drop-down menu:
l
Intellimix Room
l
P300
l
SCM-820
l
Q-SYS
l
Tesira
Turning on an adjudicator will add a fifth Adjudicator Channel column to the table. Enter the
channel number from which the automix from each device is routed to the adjudicator.
NOTE:If using an adjudicator as a device in the device list, enter the Used Channels as
normal, and set the Spare Channels and Adjudicator Channel values to 0.