system at a rate that exceeds the certified performance and the system may not
provide the necessary UV dose to remove all pathogens.
Temperature Requirements:
Where the unit is installed, the ambient temperature should be between 7–38°C
(45–100°F). If the temperature drops below freezing, drain the unit completely to
prevent damage (see Draining Instructions page 26). The water temperature
range is 1–38°C (34–100°F). Special Note: Drafts or areas where cold air is
blowing on the system can adversely affect the temperature – make sure the
system is free from cold air currents). If cold room conditions cannot be avoided,
the Cold Air Kit should be installed.
Energy Requirements:
There are two standard operating voltages for the Hallett unit. The unit may be
120Vac or 220-240 Vac. Please refer to the power input label located near the
power cord entry of the unit. See Figure 1B. For convenience the front cover of
the manual should also contain model number and operating voltage.
120Vac Models 220-240Vac Model
Hallett 13 – 104W, 1.5A max. 50/60Hz Hallett 13 -108W, 1A max. 50/60Hz
Hallett 30 - 173W, 1.5A max. 50/60Hz Hallett 30 -177W, 1A max. 50/60Hz
The unit requires a standard grounded receptacle.
Safety Information
WARNING: Potential Shock Hazard
Use only a grounded electrical outlet when connecting the unit to a power
source. If you do not know whether the outlet is grounded, check with a qualified
electrician. Do not plug in unit if water is present on the unit.
WARNING: Ultraviolet Light Hazard
The lamps in the unit emit ultraviolet (UV) light that can cause permanent
damage to the skin & eyes. Never look at the lamp when it is operating. Do
not plug the unit in unless it is properly secured to a wall (see Installation
Instructions) and all the covers are installed. Do not remove any cover unless
the unit has been unplugged. Never look into the unit or place any exposed skin
into the illuminated areas when it is operating. Do not operate a unit that has
been damaged or missing any components.
The Hallett unit is not intended for use by young children or infirm persons
without supervision. Young children should be supervised to ensure that they do
not play with the Hallett unit.