28
Released on 10/31/05 - X800058A UV Pure Technologies Inc. © 2005
No part of this document may be photocopied, reproduced, transmitted, or translated to another language without the
prior written consent of UV Pure Technologies Inc.
For additional info call 1-888-407-9997 or email info@uvpure.com
or visit www.uvpure.com
down on the top of the lamp. Do not twist the lamps when they are installed.
The lamp will come to rest when the lamp pins are fully inserted into the socket.
When pressing down, be sure to position the lamp ceramic end in the centre of
the hole in the aluminum top plate. Repeat for the other side.
Step 5: Replace the top cover and screw. Note that the slots on the either side of
the top cover must align with the top wall bracket.
Step 6: Record the date of the lamp replacement in your Service Record Sheet.
Step 7: Plug in the unit.
Step 8: Wait for the start-up sequence to end, then push and hold the "Reset"
button for six seconds to reset the internal timer – the audible alarm will beep
indicating reset acknowledged. New lamps may take from a few moments to
several hours to reach full power. Continue to run the unit until the lamps
reach full power. The solenoid valve will remain closed until the lamps have
reached full power.
Draining the Unit
The Hallett does not normally require draining for routine operation or lamp
replacement. Draining is necessary to disassemble the system, to protect against
freezing, or to remove poor-quality water.
Step 1: Shut off the water supply.
Step 2: Unplug the unit from the electrical outlet.
Step 3: Place a bucket under the unit to collect the water.
Step 4: Open a faucet downstream of the unit.
Step 5: If you have installed the optional drain valve, open the drain valve. If you
do not have an optional drain valve, disconnect the Stainless flexible hose below
the unit and allow the system to drain for a few minutes.
Step 6: When draining is complete, close the drain valve or reconnect the flexible
hose.
Step 7: Close any faucets that were previously opened.
Cleaning the Unit
The Hallett has automatic quartz cleaning and does not normally require
disassembly and cleaning of the quartz - the quartz will remain clear and
transparent as glass. If a component of the cleaning device fails, such as the
wiper motor, or in extreme water cases the quartz may become fouled and