To clear or delete a code simply press the BYPASS button at the address where the old code is stored.
e.g. P 3 E <BYPASS> E
3 beeps - Program light On or Flashing
When flashing back codes and values Zone indicators 1-8 are used to indicate digits 1-8. The digit 0 is indicated by
the "A" LED and 9 is indicated by the "B" LED
USER CODE OPTIONS
STANDARD USER CODE OPTIONS - P51E-P100E
Option 1 - Code is assigned to Area A
Option 2 - Code is assigned to Area B
Option 3 - Code is assigned to Area C
Option 4 - Code can Arm Area
Option 5 - Code can Disarm Area
Option 6 - Code can turn on Stay Mode
Option 7 - Code can turn off Stay Mode
Option 8 - Code can Operate Control Functions.
NOTE: Options 1, 2 & 3 set the Area/s the code is assigned to whereby options 4, 5, 6, 7 & 8 determine the
functions the code can operate for the Area/s it has been assigned.
EXTENDED USER CODE OPTIONS - P101E-P150E
Option 1 - Code can override DOTL timer
Option 2 - Code can change dialler telephone numbers
Option 3 - Code can alter the real time clock
Option 4 - User can start a print-out of the event buffer
Option 5 - User can answer an incoming call and start up/down load
Option 6 - User can enter Client Program and change their code only
Option 7 - User can enter Client Program and change all codes
Option 8 - User can allow access to Installer Program mode from Client Mode
Option 1 - Code can override DOTL timer-The user can inhibit the door open too long function of the
access control feature (Control) while in Client Mode. Refer to user manual for details.
Option 2 - Code can change dialler telephone numbers -The User can change telephone numbers
from Client Mode.
Option 3 - Code can alter the real time clock -The User can adjust the Day ,Date & Time of the
Panel Clock from Client Mode.
Option 4 - User can start a print-out of the event buffer -The User can cause a printout of the 255
event buffer to a serial printer from Client Mode.
Option 5 - User can answer an incoming call and start up/down load -The User can cause the
panel to answer an in-coming call for upload/download from Client Mode. See P835E on Page 53.
Option 6 - User can enter Client Program and change their code only -The User can change
their own code only from Client Mode.
Option 7 - User can enter Client Program and change all codes -The User can change any of the
24 User codes from Client Mode.
Option 8 - User can allow access to Installer Program mode from Client Mode – Access to
Installer Mode can be granted by this user from Client Mode.
NOTE: If a user has option 7 or 8 assigned to their code then they can also initiate Walk-test Mode
(P836E) from Client Program Mode.
USER CODE TIME ZONES - P151E-P200E
Users codes may have Time Zones assigned to control their operation. These Time Zones determine when a