Page 25
Option 1 Any Bypass to output #1 - This option will produce a change of state at output #1 if any zones are
bypassed, either manually or automatically. This change of state will occur at the end of the Exit delay.
The output reset time (P551E) should be set to zero when this option is enabled.
Option 2 Auto-Bypass warning to output #1 - This option will produce a 2 second pulse at output #1 at the end
of the exit period if a zone has been Auto-Bypassed in Area "A". An Auto-Bypass occurs when a zone is
left un-sealed at the end of the exit delay. At the end of the exit delay zones not defined as Auto-Bypass
which are left un-sealed will produce an activation. Auto-Bypass assignments are found at P447E and
P467E
Option 3 Entry beeps to output #1 - This option will map the keypad entry beeps to output #1.
Option 4 Exit beeps to output #1 - This option will map the keypad exit beeps to output #1.
Option 5 Control function to output #1 - This option maps the control functions in Area "A" to output #1. Control
function parameters for Area "A" are defined at P301E options 5-8
Option 6 Arm indication to output #1 - This option will turn output #1 on when Area "A" is armed and turn output
#1 off when Area "A" is disarmed. This change of state occurs at the start of the exit delay and when the
Area is disarmed. Output reset time should be set to zero (P551E0E)
Option 7 Stay Mode Arm indication to output 1 - This option will turn output #1 on when Area "A" is placed in
Stay Mode and turn output #1 off when Area "A" Stay Mode is turned off. Like option 6 this change of
state occurs either at the start of the exit delay or when the Area is disarmed. Output reset time should
be set to zero (P551E0E)
Option 8 Disarm indication to output #1 - This option will turn output #1 on when Area "A" is disarmed either
from Full Arm or Stay Mode and turn output #1 off when Area "A" is Armed or in Stay Mode. Like option
6 this change of state occurs either at the start of the exit delay or when the Area is disarmed. Output
reset time should be set to zero (P551E0E)
Note: P292E through P298E are as above but apply to outputs 2-8 for Area A
Note: P392E through P398E are as above but apply to outputs 2-8 for Area B
Note: P492E through P498E are as above but apply to outputs 2-8 for Area C
SPECIAL AREA ARM & STAY BUTTON OPTIONS FOR AREA A - P299E & P300E
SPECIAL AREA ARM & STAY BUTTON OPTIONS FOR AREA B - P399E & P400E
SPECIAL AREA ARM & STAY BUTTON OPTIONS FOR AREA C - P499E & P500E
P299E "ARM" key can disarm Area “A” during exit delay - This option enables the one key disarm during
exit delay feature on a keypad by keypad basis for each area. Options 1-8 represent keypads 1-8.
P300E "STAY" key can disarm Area “A” during Stay Mode - This option enables single button disarm of
Stay mode via the "STAY" key. Options 1-8 represent keypads 1-8
Note: P399E & P400E are as above but apply to keypads in Area B
Note: P499E & P500E are as above but apply to keypads in Area C
AREA "A" TIME ZONE AUTO ARM/DISARM OPTIONS - P290E
AREA "B" TIME ZONE AUTO ARM/DISARM OPTIONS - P390E
AREA "C" TIME ZONE AUTO ARM/DISARM OPTIONS - P490E
P290E 1-8 Time Zone to use for Auto Arm or Disarm of Area “A” (Default 0) - This option will determine
which Time Zone/s will cause Area "A" to arm, disarm or both, based on the programmed options
set at P303E for Area A.
Note: P390E is the same as above but applies to Area B Time Zone Arm/Disarm
Note: P490E is the same as above but applies to Area C Time Zone Arm/Disarm
AREA "A" TIME AND DELAY OPTIONS - P303E
AREA "B" TIME AND DELAY OPTIONS - P403E
AREA "C" TIME AND DELAY OPTIONS - P503E