Page 27
more than one area.
Option 3 Stay key required before code to arm Stay Mode - This option determines if the "STAY" key is a
single button function or must be pressed followed by a code to turn on Stay Mode in Area "A". This
option must be enabled where a keypad is assigned to more than one area. If off, Stay mode is turned
on by pressing the Stay button only, if on, you must enter a code after pressing the stay button. When
Arming Stay Mode, if the user presses the “Enter” button during the exit delay, this will cancel any
remaining exit delay time and make all Stay zones instant, even if they have an entry delay time
programmed.
Option 4 Code required to arm area - If this option is off the area can be armed with a single press of the arm
button, i.e. no code is required. If this option is on, a valid Area "A" user code is required to arm the
area.
Option 5 Control function requires code - This option determines if a code is required to operate the Control
function. The Control function provides the ability to operate an output from a key press rather than from
an alarm event. If this option is off, pressing the "CONTROL" key will produce an output as assigned at
P291E through P298E option 5. If the option is on, you must press “CONTROL” followed by a valid code
assigned with the control feature to operate the control output.
Option 6 Control function toggles - If this function is enabled, the output which is mapped to the control function
will toggle to the opposite state each time the control function is operated, i.e. if the output is on it will
turn off etc. If the reset time mapped to the control output is zero the output will remain on until the
control function operates again and toggles it off. If there is a reset time mapped to the control output,
the output will turn off at the end of the reset time as expected. The next time the Control function is
operated the output will come on again for the reset period then turn off.
Option 7 Control function is momentary - If this option is enabled, the output which is mapped to the control
function will turn on for the time period as determined by the value of the pulse timer mapped to the
control output.
Option 8 Control Button disables "Day/Chime" mode or directly Controls Outputs - If this option is enabled
(LED 8 On), pressing the CONTROL button will put the LED keypads in the special “Control” mode,
indicated by the Control LED turning on. At this point two operations may be performed. The first is that
Outputs can be turned On or Off by selecting the Output number/s required. Then when you are
finished, pressing the enter button will exit Control mode (for outputs to be controlled at this point option
6 at P201-P208 must be on). The second option is to press the “Program” button after pressing the
“Control” button which will disable the day alarms for the area assigned to the keypad. When the day
alarms disable mode is active the CONTROL light will be on. To restore the day function simply press
Control then Program buttons again. A similar set of options are available on the LCD keypad but to
disable day alarms you can either press and hold the “Chime’ button or hold down the Control button
and within 2 seconds also press the Program button to achieve the same result. On the LCD keypad it
shows “Chime Off” when the day alarms are disabled.
If the option is disabled (LED 8 Off) then the control button is only used to operate the Control Output/s
as assigned at addresses P291-298, 391-398, 491-498 option 5.
We advise that only one of the Control Function options be assigned at the above address.
Note: P401E is the same as above but applies to Area B Keypad options
Note: P501E is the same as above but applies to Area C Keypad options
AREA "A" MISCELLANEOUS SPECIAL OPTIONS - P302E
AREA "B" MISCELLANEOUS SPECIAL OPTIONS - P402E
AREA "C" MISCELLANEOUS SPECIAL OPTIONS - P502E
P302E 1E = Key-switch Input enabled
2E = Use 2nd Key-switch
3E = Key-switch is used for Arm or Stay
4E = Pendant chirps on Arming / disarming
5E = Pendant chirps on Stay Mode on / off
6E = 2 second output on Arming
7E = 2 second output on Disarming
8E = Access Control enabled even when Area is armed
Option 1 Key-switch Input enabled - This option will enable the Key-switch input. Operating the Key-switch
input will arm Area "A" as determined by P302E option 3. The Key-switch type is programmed at P311E