options 2, 3 & 4.
Option 2 Use 2nd Key-switch - This option will enable dual end of line configuration of the Key-switch input and
assign the high value end-of-line (8k2) to Area "A" (refer to the zone drawing on page 6 Type 3 or 4).
Also option 2 at address P311E selects whether a tamper is available when the 2nd key-switch is used.
Option 3 Key-switch is used for arm or Stay - If this option is on, operating the Key-switch will arm Area "A". If
this option is off, operating the Key-switch will turn Area "A" Stay Mode on and off.
Option 4 Pendant Chirps on arming / disarming - This option will send two short pulses (Chirps) to the output
mapped at P281E - P288E option 3 when Area "A" is armed via a radio key (Pendant) and four short
pulses to the output when Area "A" is disarmed by a radio key.
Option 5 Pendant Chirps on Stay Mode on / off - This option will send two short pulses (Chirps) to the output
mapped at P281E - P288E option 3 when Stay Mode for Area "A" is turned on with a radio key
(Pendant) and four short pulses to the output when Area "A" Stay Mode is turned off by a radio key.
Option 6 2 second output on Arming - If this option is on, the output which is assigned by P281E - P288E
option 5 will turn on for 2 seconds when Area "A" is armed.
Option 7 2 second output on Disarming - If this option is on, the output which is assigned by P281E - P288E
option 5 will turn on for 2 seconds when Area "A" is disarmed.
Option 8 Access Control enabled even when area is armed - If this option is enabled, the Access Control
functions, as determined by P456E, P457E, P476E and P477E will work at all times, even when Area
"A" is in the armed condition.
Note: P402E is the same as above but applies to Area B Miscellaneous options
Note: P502E is the same as above but applies to Area C Miscellaneous options
AREA BASED DIALLER REPORTING OPTIONS - P289E
P289E 1-8E Area A Reporting Options - Default 1,2
1 = Send Arm/Disarm
2 = Send Stay Mode Arm/Disarm
3 = Send Disarm only after activations
4 = Send Stay Disarm only after activations
5 = Send Arm at the end of the exit delay
6 = Send all zone restores when disarmed
7 = Spare
8 = Spare
Option 1 Send Arm / Disarm - If this option is on, the dialler will report Area "A" arms and disarms.
Option 2 Send Stay Mode Arm / Disarm - If this option is on, the dialler will report Area "A" stay mode
arms and disarms.
Option 3 Send Disarm only after activation - If this option is on, the dialler will report an Area A disarm
following an alarm activation only. This option is often used in conjunction with alarm only
reporting and stops the normal arm/disarm signals from being sent. If this option is on it will
override the option 1 setting.
Option 4 Send Stay Mode Disarm only after activation - If this option is on, the dialler will report an Area
A Stay Mode disarm following an alarm activation only. This option is often used in conjunction
with alarm only reporting and stops the normal Stay Mode arm/disarm signals from being sent. If
this option is on it will override the option 2 setting.
Option 5 Send Arm at the end of the exit delay - If the LED is Off, the dialler will report an Arm
immediately the panel is armed. If the LED is On, the Arm report is sent at the expiry of the exit
delay.
Option 6 Send all zone restores when disarmed - If this option is off, the dialler will send all zone
restores as they occur. If the option is on, the dialler will send all zone restores only when the
panel is disarmed. If the option is On, only one restore will be sent for each zone that activates
regardless of whether the zones can send multiple alarm reports