Page 60
P235E Output #5 Automatic on / off time zones - Default 0 (never) Page 21
P236E Output #6 Automatic on / off time zones - Default 0 (never) Page 21
P237E Output #7 Automatic on / off time zones - Default 0 (never) Page 21
P238E Output #8 Automatic on / off time zones - Default 0 (never) Page 21
P241E Output #1 Enable time zones - Default 0 (always) Page 21
P242E Output #2 Enable time zones - Default 0 (always) Page 21
P243E Output #3 Enable time zones - Default 0 (always) Page 21
P244E Output #4 Enable time zones - Default 0 (always) Page 21
P245E Output #5 Enable time zones - Default 0 (always) Page 21
P246E Output #6 Enable time zones - Default 0 (always) Page 21
P247E Output #7 Enable time zones - Default 0 (always) Page 21
P248E Output #8 Enable time zones - Default 0 (always) Page 21
Programming Installer Code
P249E Installer Code - Default 000000 - must be more than 3 digits long Page 19
Programming Keypad Options
P250E Keypads assigned to Area "A" - Default 1-8 Page 22
P251E Keypads assigned to Area "B" - Default none Page 22
P252E Keypads assigned to Area "C" - Default none Page 22
P253E Keypads with permission to Arm - Default 1-8 Page 22
P254E Keypads with permission to Arm Stay Mode - Default 1-8 Page 22
P255E Keypads with permission to use control function - Default 1-8 Page 22
P256E Keypads with permission to bypass zones - Default 1-8 Page 22
P257E Keypads (LED) with Panic Button enabled - Default 1-8 Page 22
P258E Keypads (LED) with Delayed Panic Button enabled - Default 1-8 Page 22
P259E Keypads with buttons 1 & 3 Panic Alarm enabled - Default 1-8 Page 22
P260E Keypads with buttons 4 & 6 Fire Alarm enabled - Default 1-8 Page 22
P261E Keypads with buttons 7 & 9 Medical Alarm enabled - Default 1-8 Page 22
P262E Keypads with buzzer mapped for alarm tone for armed zone alarms - Default 1-8 Page 22
P263E Keypads with buzzer mapped for alarm tone for stay mode zone alarms - Default 1-8 Page 22
P264E Keypads with buzzer mapped for alarm tone for 24 hour zone alarms - Default 1-8 Page 23
P265E Keypads with buzzer mapped for alarm tone for day mode zones - Default 1-8 Page 23
P266E Keypads with buzzer mapped to indicate Arm Mode exit delay beeps - Default 1-8 Page 23
P267E Keypads with buzzer mapped to indicate Stay Mode exit delay beeps - Default 1-8 Page 23
P268E Keypads with buzzer mapped to indicate entry delay beeps - Default 1-8 Page 23
P269E Keypads with buzzer mapped for supervised radio timeout, or zone inactivity alarm - Default 1-8 Page 23
P270E Keypads with buzzer mapped to keypad tamper - Default 1-8 Page 23
P271E Keypads with buzzer mapped to zone tamper - Default 1-8 Page 23
P272E Keypads with buzzer mapped to cabinet tamper - Default 1-8 Page 23
P273E Keypads with buzzer mapped to Radio Pendant “Panic” Alarm - Default 1-8 Page 23
P274E Keypads with buzzer mapped to “Panic” Alarm - Default 1-8 Page 23
P275E Keypads with buzzer mapped to “Fire” Alarm - Default 1-8 Page 23
P276E Keypads with buzzer mapped to “Medical” Alarm - Default 1-8 Page 23
P277E Keypads with buzzer mapped to line failure - Default none Page 23
P278E Keypads with facility to turn off LED's after exit delay - Default none Page 23
Partition “A” Primary Output Options
P281E-P288E OPTIONS
P281E Area "A" primary options for output #1 - Default 1 1 = Standard zone activation's Page 24
P282E Area "A" primary options for output #2 - Default 1 & 2 2 = Stay Mode activation's Page 24
P283E Area "A" primary options for output #3 - Default 1 3 = Radio key chirps Page 24
P284E Area "A" primary options for output #4 - Default 1 4 = All zones sealed (ready) Page 24
P285E Area "A" primary options for output #5 - Default 1 5 = 2 sec pulse on arm / disarm Page 24
P286E Area "A" primary options for output #6 - Default 1 6 = Spare Page 24
P287E Area "A" primary options for output #7 - Default 1 7 = Day zone activation's Page 24
P288E Area "A" primary options for output #8 - Default 1 8 = Spare Page 24
** Dialler Reporting Options for partition “A” **
P289E Area A reporting options -Default = 1,2 Page 28