Option 7 Pulse on Arming to output - This option will map a pulse to the Output each time Area"A" is armed
( the length of the pulses is set by the pulse timer P221E-P228E).
Option 8 Pulse on Disarming to output - This option will map a pulse to the Output each time Area"A" is
disarmed ( the length of the pulses is set by the pulse timer P221E-P228E).
Note: P112E through P118E are as above but applied to outputs 2-8
PARTITION “B” OPTIONS
PARTITION “B” OPTIONS - P120E
This address allows modification of how Partition “B” arming, STAY and control keys work at the keypad.
P120E 1E “ARM” button required before code to set- Default off
2E “STAY” button required before code to turn on Stay Mode- Default off
3E “CODE” required to arm- Default off
4E ARM” button can disarm system during exit delay- Default on
5E “STAY” button can disarm Stay Mode at any time- Default on
6E No Exit Beeps to keypads in Stay Mode- Default off
7E Key-switch Enabled- Default off
8E Key-switch Mode- Default off
Option 1 “ARM” button required before code to set - This option determines if the “ARM” button must be
pressed before a code is entered to set Area “B”. If a keypad is assigned to both Partitions, this
option should be set to allow individual arming of each area. This option disables the Arm button from
disarming during the exit delay.
Option 2 “STAY” button required before code to set - This option determines if the “STAY” button must be
pressed before a code is entered to set Area “B” Stay Mode. If a keypad is assigned to both
Partitions, this option should be set to allow individual arming of Stay Mode for each area.
Option 3 “CODE” required to set - If this option is set, the “ARM” button is disabled and the panel requires a
code to arm as well as disarm.
Option 4 ARM” button can disarm during exit delay - If this option is on then the “arm” button can disarm
Partition “B” during the exit delay time with a single press of the button. If the option is off then the
alarm can only be unset by a valid code, even during the exit delay time.
Option 5 “STAY” button can disarm Stay Mode - This option allows the “Stay” button to disarm STAY mode
at any time (including when Stay Mode is fully set). If the option is off then Stay Mode can only be
unset by a valid code. This feature is defaulted to keypad addresses 1 & 4 ( 4 being the default
address for the STAY key station).
Option 6 No Exit Beeps to keypads in Stay Mode - This option stops the exit beeps from occurring at all
keypads when Stay Mode is set. Normally used for silent night arming.
Option 7 Enable Partition “B” Key-switch - If this option is turned on then the system tamper input (Tmp)
becomes a Dual End of Line Input (Refer to Type 4 drawing on Page 5 for wiring details). The high
input 8K2 is reserved for Partition “B” key-switch operation. An open circuit will still be seen as a
system tamper.
Option 8 Key-switch Mode - If this option is On then the key-switch has a toggle function (ie the arm/disarm
state will follow the key-switch state). If Off then the key-switch is momentary (ie each single pulse
AreaA Opt O/P 1
- - - - - - - -