EasyManua.ls Logo

Crow PowerWave-4 - Keypad Partition Assignment

Crow PowerWave-4
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 29
pendants. To prevent confusion, if a pendant is set to control an output or provide instant Panic, then you should
turn off any Arm or Disarm options at addresses P151E-P158E.
P161E-Pendant #1 Options 1E Turn output ON - Default off
2E Turn output OFF - Default off
3E Visonic Powercode Battery Low - Default off
4E Spare - Default off
5E Report Pendant Panic To Dialer - Default off
6E Immediate Panic Alarm - Default off
7E Delayed Panic Alarm (1.5 Seconds) - Default off
8E Ness Battery Low - Default off
Option 1 Turn Output On - This option allows the pendant to turn an output on. The output the pendant will
turn On is programmed at address P101E-P108E. If the output reset time is set to Latched operation
(set to “0”) then you must also program Option 2 to the pendant to allow for turning the output Off.
Option 2 Turn Output Off - This option allows the pendant to turn an output off. The output the pendant will
turn Off is programmed at address P101E-P108E. For this option to work, option 1 above must also
be assigned to the pendant to allow the pendant to first turn the output on before it can turn it off.
Option 3 Visonic Powercode Battery Low - If a Visonic Powercode Transmitter with battery low monitoring is
used on the PW-4, setting this option will allow the battery signal to be correctly recognised.
Option 4 Spare
Option 5 Report Panic to Dialer- This option enables a panic alarm from a pendant to be sent via the dialer to
a Monitoring Station.
Option 6 Immediate Panic Alarm - If this option is on, pressing the pendant button will produce a pendant
panic alarm. The Panic alarm can also be silent at the keypad or sound the keypad buzzer (see
P175E)
Option 7 Delayed Panic Alarm- If this option is on, the pendant button must be pressed continuously for 1.5
seconds or longer to produce a pendant panic alarm.
Option 8 Ness Battery Low - If using a Ness pendant with battery low reporting, this option must be turned on
to allow the battery low signal to be recognized properly.,
Note: P162E through P168E are as above but applied to pendants 2-8
KEYPAD PARTITION ASSIGNMENT
A keypad must be assigned to a Partition before it can control the Partition (ie to allow Arm/Disarm facilities).
P171E Keypads Assigned to Partition “A” - Option Keypad 1-8 (Default = All keypads 1-8)
P172E Keypads Assigned to Partition “B” - Option keypad 1-8 (Default = None)
Pendant 1 Opt B
- - - - - - - -
KeyPad in A
1 2 3 4 5 6 7 8

Table of Contents