EasyManua.ls Logo

Crow PowerWave-4 - Output Timing Options; Output Reset Time-P311 E-P318 E (0-9999 Seconds)

Crow PowerWave-4
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 25
DAY MODE TO KEYPAD BUZZER TIMER
These addresses can be programmed to have a value from 0 to 99 but the value is in 1/10 of a
second increments. This means the default of 20 at addresses P209E & P210E is equal to 2
seconds. This gives a much greater control on the duration of the day zone beep to the keypad.
P209E Area “A” Day Mode to Keypad Buzzer Timer - 0-99 (Default = 20 1/10th sec)
P210E Area “B” Day Mode to Keypad Buzzer Timer - 0-99 (Default = 20 1/10th sec)
OUTPUT TIMING OPTIONS
OUTPUT RESET TIME-P311E-P318E (0-9999 Seconds)
The output reset time is how long an output will stay on following an alarm condition. A value of “0”
means the output will latch until reset by a valid user code.
P311E Output 1 Alarm Reset Time - (Default = 300 Sec)
P312E Output 2 Alarm Reset Time - (Default = 300 Sec)
P313E Output 3 Alarm Reset Time - (Default = 0 Sec)
P314E Output 4 Alarm Reset Time - (Default = 0 Sec)
P315E Output 5 Alarm Reset Time - (Default = 0 Sec)
P316E Output 6 Alarm Reset Time - (Default = 0 Sec)
P317E Output 7 Alarm Reset Time - (Default = 0 Sec)
P318E Output 8 Alarm Reset Time - (Default = 0 Sec)
OUTPUT DELAY ON TIME-P201E-P208E (0-99 Seconds)
The output delay ON time is how long an output will be delayed before turning on following an alarm
condition.
P201E Output 1 Delay On Time - (Default = 0 Sec)
P202E Output 2 Delay On Time - (Default = 0 Sec)
P203E Output 3 Delay On Time - (Default = 0 Sec)
P204E Output 4 Delay On Time - (Default = 0 Sec)
P205E Output 5 Delay On Time - (Default = 0 Sec)
P206E Output 6 Delay On Time - (Default = 0 Sec)
P207E Output 7 Delay On Time - (Default = 0 Sec)
P208E Output 8 Delay On Time - (Default = 0 Sec)
OUTPUT DAY MODE TIME-P211E-P218E (0-99 1/10th Second)
The output day mode timer is how long an output will turn on following a day zone unsealing. The
Day Mode Timer is in 1/10th Sec intervals e.g. 20=2 Seconds
P211E Output 1 Day Mode Time - (Default = 20)
P212E Output 2 Day Mode Time - (Default = 20)
P213E Output 3 Day Mode Time - (Default = 20)
P214E Output 4 Day Mode Time - (Default = 20)
P215E Output 5 Day Mode Time - (Default = 20)
P216E Output 6 Day Mode Time - (Default = 20)
P217E Output 7 Day Mode Time - (Default = 20)
P218E Output 8 Day Mode Time - (Default = 20)
OUTPUT PULSE TIMER-P221E-P228E (0-99 1/10th Second)
The output pulse timer is how long an output will turn on when the pulse timer is used. The Pulse
Timer is in 1/10th Sec intervals e.g. 20=2 Seconds
P221E Output 1 Pulse Timer - (Default = 20)
P222E Output 2 Pulse Timer - (Default = 20)
AreaA Chime time
20
O/P 1 Reset Time
300
O/P 1 Delay Time
0
O/P 1 Chime Time
20

Table of Contents