Page 42
ZONE CONTACT ID CODE
This block of addresses (P321E - P324E) are used to set the Contact ID code that a Zone will transmit in an alarm. If
a value of “0” or the “Bypass” button is entered at any of these addresses then the zone will not report via the Dialer.
P321E Zone # 1 Contact ID Code - 3 Digit Number (Default = 130)
P322E Zone # 2 Contact ID Code - 3 Digit Number (Default = 130)
P323E Zone # 3 Contact ID Code - 3 Digit Number (Default = 130)
P324E Zone # 4 Contact ID Code - 3 Digit Number (Default = 130)
PANIC ALARM CONTACT ID CODE
This address (P329E) is used to set the Contact ID code that a Keypad “Panic” or “1&3” alarm will transmit.
P329E Keypad Panic Alarm Contact ID Code - 3 Digit Number (Default = 120)
FIRE ALARM CONTACT ID CODE
This address (P330E) is used to set the Contact ID code that a Keypad Fire “4&6” alarm will transmit.
P330E Keypad Fire Alarm Contact ID Code - 3 Digit Number (Default = 110)
MEDICAL ALARM CONTACT ID CODE
This address (P331E) is used to set the Contact ID code that a Keypad Medical “7&9” alarm will transmit.
P331E Keypad Medical Alarm Contact ID Code - 3 Digit Number (Default = 100)
PROGRAMMING DIALER 4 + 2 REPORTING CODES
The dialer is capable of reporting most events in 4+2 format to a monitoring station. There are various 4+2 formats
(see telephone mode options on page 40).
The 4+2 format consists of a 4 character account code, plus a 2 character event code. The account & event codes
can be any combination of the values 1234567890BCDEF (see programming chart on page 32). If a value of “00” is
CID for Zone1
130
CID for Panic
120
CID for Fire
110
100
CID for Medic