EasyManua.ls Logo

Crow PowerWave-4 - Page 43

Crow PowerWave-4
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 43
programmed into any 4+2 address (or the “Bypass” key is entered at a selected 4+2 address) then no report will be
generated for that event.
ZONE ALARM 4 + 2 REPORTING CODE
This block of addresses (P511E - P514E) are used to set the 4 + 2 code that a Zone will transmit in an alarm.
P511E Zone # 1 4 + 2 Code - 2 Digit Number (Default = 01)
P512E Zone # 2 4 + 2 Code - 2 Digit Number (Default = 02)
P513E Zone # 3 4 + 2 Code - 2 Digit Number (Default = 03)
P514E Zone # 4 4 + 2 Code - 2 Digit Number (Default = 04)
ZONE ALARM 4 + 2 RESTORE CODE
This block of addresses (P521E - P524E) are used to set the 4 + 2 code that a Zone will transmit when it is restored
following an alarm.
P521E Zone # 1 4 + 2 Code - 2 Digit Number (Default = 11)
P522E Zone # 2 4 + 2 Code - 2 Digit Number (Default = 12)
P523E Zone # 3 4 + 2 Code - 2 Digit Number (Default = 13)
P524E Zone # 4 4 + 2 Code - 2 Digit Number (Default = 14)
ZONE BYPASSED 4 + 2 CODE
This block of addresses (P581E - P584E) are used to set the 4 + 2 code that a Zone will transmit if it is manually or
automatically excluded at the time of Arming.
P581E Zone # 1 Bypassed 4 + 2 Code - 2 Digit Number (Default = 21)
P582E Zone # 2 Bypassed 4 + 2 Code - 2 Digit Number (Default = 22)
P583E Zone # 3 Bypassed 4 + 2 Code - 2 Digit Number (Default = 23)
P584E Zone # 4 Bypassed 4 + 2 Code - 2 Digit Number (Default = 24)
ZONE BYPASSE RESTORE 4 + 2 CODE
This block of addresses (P591E - P594E) are used to set the 4 + 2 code that a Zone will transmit if a manual or
automatic exclusion has been restored.
P591E Zone # 1 Bypass Restore 4 + 2 Code - 2 Digit Number (Default = 31)
P592E Zone # 2 Bypass Restore 4 + 2 Code - 2 Digit Number (Default = 32)
P593E Zone # 3 Bypass Restore 4 + 2 Code - 2 Digit Number (Default = 33)
P594E Zone # 4 Bypass Restore 4 + 2 Code - 2 Digit Number (Default = 34)
MISCELLANEOUS 4 + 2 REPORTING CODES
This block of addresses are used to set the 4 + 2 code for Miscellaneous reporting functions
4+2 Alarm Zone 1
A1
11
4+2 Restr Zone 1
4+2 Byp Zone 1
21
21
4+2 Byp Zone 1

Table of Contents