EasyManua.ls Logo

Crow PowerWave-4 - Armed by User 4+2 Code

Crow PowerWave-4
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 44
P519E System Tamper 4 + 2 Code - 2 Digit Number (Default = 86)
P531E Panic Alarm 4 + 2 Code - 2 Digit Number (Default = 88)
P532E Fire Alarm 4 + 2 Code - 2 Digit Number (Default = 89)
P533E Medical Alarm 4 + 2 Code - 2 Digit Number (Default = 90)
P537E Low Battery 4 + 2 Code - 2 Digit Number (Default = 94)
P538E Mains Failure 4 + 2 Code - 2 Digit Number (Default = 95)
P590E Automatic Test 4 + 2 Code - 2 Digit Number (Default = 85)
MISCELLANEOUS 4 + 2 RESTORE CODES
This block of addresses are used to set the 4 + 2 code for Miscellaneous restore reporting functions
P529E System Tamper Restore 4 + 2 Code - 2 Digit Number (Default = 87)
P534E Panic Alarm Restore 4 + 2 Code - 2 Digit Number (Default = 91)
P535E Fire Alarm Restore 4 + 2 Code - 2 Digit Number (Default = 92)
P536E Medical Alarm Restore 4 + 2 Code - 2 Digit Number (Default = 93)
P539E Low Battery Restore 4 + 2 Code - 2 Digit Number (Default = 96)
P540E Mains Failure Restore 4 + 2 Code - 2 Digit Number (Default = 97)
ARMED BY USER 4 + 2 CODE
This block of addresses are used to set the 4 + 2 code that will transmitted each time an individual User Arms the
alarm system.
P541E Armed by User # 1 4 + 2 Code - 2 Digit Number (Default = 41)
P542E Armed by User # 2 4 + 2 Code - 2 Digit Number (Default = 42)
P543E Armed by User # 3 4 + 2 Code - 2 Digit Number (Default = 43)
P544E Armed by User # 4 4 + 2 Code - 2 Digit Number (Default = 44)
P545E Armed by User # 5 4 + 2 Code - 2 Digit Number (Default = 45)
P546E Armed by User # 6 4 + 2 Code - 2 Digit Number (Default = 46)
P547E Armed by User # 7 4 + 2 Code - 2 Digit Number (Default = 47)
P548E Armed by User # 8 4 + 2 Code - 2 Digit Number (Default = 48)
P548E Armed by User # 9 4 + 2 Code - 2 Digit Number (Default = 49)
P550E Armed by User #10 4 + 2 Code - 2 Digit Number (Default = 50)
P569E Armed by “ARM” Button or Key-switch 4 + 2 Code - 2 Digit Number (Default = 81)
P570E Stay Mode Arming 4 + 2 Code - 2 Digit Number (Default = 82)
DISARMED BY USER 4 + 2 CODE
This block of addresses are used to set the 4 + 2 code that will transmitted each time an individual User Disarms the
alarm system.
P551E Disarmed by User # 1 4 + 2 Code - 2 Digit Number (Default = 51)
P552E Disarmed by User # 2 4 + 2 Code - 2 Digit Number (Default = 52)
P553E Disarmed by User # 3 4 + 2 Code - 2 Digit Number (Default = 53)
P554E Disarmed by User # 4 4 + 2 Code - 2 Digit Number (Default = 54)
P555E Disarmed by User # 5 4 + 2 Code - 2 Digit Number (Default = 55)
P556E Disarmed by User # 6 4 + 2 Code - 2 Digit Number (Default = 56)
P557E Disarmed by User # 7 4 + 2 Code - 2 Digit Number (Default = 57)
P558E Disarmed by User # 8 4 + 2 Code - 2 Digit Number (Default = 58)
P559E Disarmed by User # 9 4 + 2 Code - 2 Digit Number (Default = 59)
P560E Disarmed by User #10 4 + 2 Code - 2 Digit Number (Default = 60)
P579E Disarmed by “Arm” Button or Key-switch 4 + 2 Code - 2 Digit Number (Default = 83)
4+2 Low Battery
94
92
4+2 Fire Restr
4+2 Arm User 1
41
4+2 DisArm User1
51

Table of Contents