Page 19
Option 5 “STAY” button can disarm Stay Mode - This option allows the “Stay” button to disarm STAY mode
at any time (including when Stay Mode is fully set). If the option is off then Stay Mode can only be
unset by a valid code. This feature is defaulted to keypad addresses 1 & 4 ( 4 being the default
address for the STAY key station).
Option 6 No Exit Beeps to keypads in Stay Mode - This option stops the exit beeps from occurring at all
keypads when Stay Mode is set. Normally used for silent night arming.
Option 7 Enable Partition “A” Key-switch - If this option is turned on then the system tamper input (Tmp)
becomes a Dual End of Line Input (Refer to Type 4 drawing on Page 4 for wiring details). The low
input 4K7 is reserved for Partition “A” key-switch operation. An open circuit will still be seen as a
system tamper.
Option 8 Key-switch Mode - If this option is On then the key-switch has a toggle function (ie the arm/disarm
state will follow the key-switch state). If Off then the key-switch is momentary (ie each single pulse
will change the arm/disarm state). The panel tamper input is used to provide the key-switch function.
PARTITION “A” OUTPUT OPTIONS
PARTITION “A” OUTPUT OPTIONS - P111E - P118E
This block of addresses sets a number of output options which are specific and unique to the operation of partition
or Area "A". Activity in Areas "B" will have no direct effect on the options set at these addresses.
P111E 1E Arm status to output- Default off (P113E=ON)
2E Stay Mode on status to output- Default off (P113E=ON)
3E Disarm status to output- Default off (P113E=ON)
4E Pendant chirps for Arm to output - Default off
5E Pendant chirps for Stay Mode On to output - Default off
6E Pendant chirps for Disarm to output - Default off
7E Pulse on Arming to output - Default off (P114E=ON)
8E Pulse on Disarming to output - Default off
Option 1 Arm indication to output - This option will turn the output on when Area "A" is armed. The output
will turn on at the start of the exit delay and turn off when the Area is disarmed. The output reset time
should be set to zero.
Option 2 Stay Mode On indication to output - This option will turn the output on when Area "A" Stay Mode is
armed. The output will turn on at the start of the exit delay and turn off when Stay Mode is disarmed.
The output reset time should be set to zero.
Option 3 Disarm indication to output - This option will turn the output on when Area "A" is Disarmed. The
output will turn on when the Area “A” is disarmed and turn off when the Area is Armed or in Stay
Mode. The output reset time should be set to zero.
Option 4 Pendant Chirps for Arm to output - This option will map two short pulses (Chirps) to the output
when Area "A" is armed via a radio key (Pendant) ,( the length of the pulses is set by the pulse timer
P221E-P228E).
Option 5 Pendant Chirps for Stay Mode On to output - This option will map two short pulses (Chirps) to the
output when Area "A" Stay Mode is set via a radio key (Pendant) ,( the length of the pulses is set by
the pulse timer P221E-P228E).
Option 6 Pendant Chirps for Disarm to output - This option will map four short pulses (Chirps) to the output
when Area "A" is Disarmed via a radio key (Pendant) ,( the length of the pulses is set by the pulse
timer P221E-P228E).