Page 37
panel to only communicate in one format. If the LED is off the format is Bell 103, LED on means V21.
DIALER REPORTING OPTIONS “A”
This address (P186E) is used to enable or disable various alarm reports to the Dialer.
P186E 1E Report Duress Alarm - Default on
2E Report Mains Fail - Default on
3E Report Battery Low - Default off
4E Report Radio Battery Low - Default on
5E Report System Tamper - Default on
6E Report Telephone line Failure - Default on
7E Report Supervised Radio Fault - Default on
8E Report Zone Inactivity Alarm - Default on
Option 1 Duress Alarm to Dialer - If a duress alarm is created the panel can report the unsetting of the alarm
under duress to a central monitoring company if this option is on.
Option 2 Report Mains Fail - If a mains failure is detected the panel can report this alarm to a central monitoring
company if this option is on.
Option 3 Report Battery Low - If a battery low is detected the panel can report this alarm to a central monitoring
company if this option is on.
Option 4 Report Radio Battery Low - If a Radio battery low is detected the panel can report this alarm to a
central monitoring company if this option is on.
Option 5 Report System Tamper - If a control panel tamper is detected the panel can report this alarm to a
central monitoring company if this option is on.
Option 6 Report Line Failure - If a telephone line failure is detected the panel can report this alarm to a central
monitoring company if this option is on.
Option 7 Report Supervised Radio Fault - If a supervised radio device fails to report to the panel within a
preset time then a radio failure is registered. If this option is turned on then the alarm will be reported to the
monitoring company.
Option 8 Report Zone Inactivity Alarm - If a Zone is monitored for Inactivity (P150E) and the inactivity timer for
that zone times out (P240E) an alarm will be generated. If this option is turned on then the alarm will be
reported to the monitoring company.
DIALER REPORTING OPTIONS “B”
This address (P187E) is used to enable or disable various alarm reports to the Dialer.
P187E 1E Report Keypad Panic Alarms - Default on
2E Report Keypad Manual Fire Alarms (4&6) - Default on
3E Report Keypad Manual Medical Alarms (7&9) - Default on
4E Spare
1 2 - - - - 7 -
Dialer Options
Dialer Report 1
1 2 - 4 5 6 7 8