Page 55
Two Trigger Timer
P229E Two Trigger Timer - Value 0-255 Seconds (Default = 60 Sec) Page 24
Duress Digit
P230E Duress Digit - Value 1-9 (Default = 0 Duress Function Disabled) Page 33
Radio Zone Detector Options
P231E Options for Zone # 1 (Default= 0) P231E-P234E Options Page 26
P232E Options for Zone # 2 (Default= 0) 1 = Crow AE Series Battery low Page 26
P233E Options for Zone # 3 (Default= 0) 2 = Crow AE Radio Reed Switch Page 26
P234E Options for Zone # 4 (Default= 0) 3 = Crow Merlin PIR (supervised signal ignored) Page 26
4 = Crow Merlin PIR (supervised signal active) Page 26
11 = Ness Devices battery Low Page 26
12 = Ness Radio Reed Switch Page 26
21 = Electronics Line Radio PIR Page 26
31 = Visonic K900 Radio PIR Page 26
32 = Visonic Powercode (supervised signal ignored) Page 26
33 = Visonic Powercode (supervised signal active)
Radio Detector Supervised Timer
P239E Radio Detector Supervised Timer - 0-255 Minutes (Default = 240 Minutes) Page 27
Zone Inactivity Timer
P240E Zone Inactivity Timer - 0-255 Hours (Default = 120 Hours) Page 24
**Telephone Number Reporting Options**
P241E Reporting Opts. Ph # 1 (Default= 2) P241E-P244E Options Page 39
P242E Reporting Opts. Ph # 2 (Default= 2) 1 = Contact ID Page 39
P243E Reporting Opts. Ph # 3 (Default= 2) 2 = Domestic Dial Page 39
P244E Reporting Opts. Ph # 4 (Default= 2) 3 = Pager Page 39
4 = Speech Dialer
5 = 4+2 10pps (Handshake 1400/ Tone 1800)
6 = 4+2 10pps (Handshake 1400/ Tone 1900)
7 = 4+2 10pps (Handshake 2300/ Tone 1800)
8 = 4+2 10pps (Handshake 2300/ Tone 1900)
9 = 4+2 20pps (Handshake 1400/ Tone 1800)
10= 4+2 20pps (Handshake 1400/ Tone 1900)
11= 4+2 20pps (Handshake 2300/ Tone 1800)
12= 4+2 20pps (Handshake 2300/ Tone 1900)
13= 4+2 DTMF
**Maximum Re-Tries per Telephone Number**
P245E Maximum re-Tries for PH No. 1 - Value 0-99 (Default = 20) Page 39
P246E Maximum re-Tries for PH No. 2 - Value 0-99 (Default = 20) Page 39
P247E Maximum re-Tries for PH No. 3 - Value 0-99 (Default = 20) Page 39
P248E Maximum re-Tries for PH No. 4 - Value 0-99 (Default = 20) Page 39