7 Installation
7.1 General notes for the Installation
Information!
Check the packaging carefully for damage. In case of damage, please contact the carrier or CS
Instruments GmbH & Co.KG.
Information!
Check the completeness of the delivery.
7.2 Storage
• Store the sensor in a dry and dust-free place
• Store the sensor in the original packaging
• The permissible storage temperatures are -40°C ... 80°C
7.3 Transport
Attention!
• There is a risk of injury from unsecured devices.
During transport, prevent the device from slipping or turning
unintentionally.
• Do not use transport chains, as these will damage the housing.
• The unit must not be lifted by the housing head for transport.
• For transport, use carrying straps which you place around both process
connections.
7.4 Pipe/tube requirements
• Correctly sized gaskets
• Correct aligned flanges and gaskets
• Diameter mismatch at the pipe junctions should be avoided but must be less
than 1mm. For further information see ISO 14511
• Ensure clean pipes after installation