Page 38 - Revision:EU-2020-10-13
C100 MINI DRAINING INSTRUCTIONS
Draining Notes
Drain the C100 Water Treatment System for transportation.
WARNING! STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbial growth).
Prior to draining the Hot Tank, turn off the Red Heater and Compressor Switch –
O=OFF, and dispense 2 Litres (½ Gallon) of hot water from the C100 Water Treatment
System. As hot water is dispensed from the Faucet of the unit, colder water will be
introduced into the Hot Tank. Since the Red Heater and Compressor Switch is turned
off, the Heater will not energize and heat the incoming tap water.
Following this precaution prevents exposing personnel and equipment (drains, catch basin, etc.)
from scalding hot water.
Disable Cold and Hot Tanks
1. Turn off the Red Heater and Compressor Switch to disable the Heater and
Compressor. Red Compressor/Heater Switch must be in the O=OFF position
2. Dispense 2 litres of water through the Hot Tank to cool the water temperature in the
Hot Tank and avoid burns.
WARNING! HOT WATER. Unit produces Hot Water up to 87
o
C (189
o
F). Water above 52
o
C
(125
o
F) can cause severe burns or scalding. Hot water should be dispensed carefully into insulated
container to avoid injury.
Turn off Water Supply and Bleed Water Pressure
3. Isolate C100 Water Treatment System from feed water by turning off the supply.
4. Dispense cold still water to relieve any pressure built up in the system.
Drain the Cold Water Tank and Circuit
5. Remove Top Cover.