Curtis 1230 Manual, Rev. C
39
3 — PROGRAMMABLE PARAMETERS: Hourmeter Parameters
HOURMETER MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Enable Total Service Hours OFF/ON When programmed Off, the total hourmeter will continue to count the total
hours of operation (i.e., KSI on-time) but no action will be taken when the
service interval elapses.
Enable Drive Service Hours
OFF/ON When programmed Off, the traction hourmeter will continue to count
the hours of drive operation but no action will be taken when the service
interval elapses.
Adjust Hours 0–999999 hours The controller is shipped from the factory with both hourmeters preset to
zero. If the controller is being installed in a used vehicle, you can transfer
the vehicle’s existing hourmeter values to the new controller.
The Adjust Hours parameter defines the hours that will be applied
as a preset value. Enter the desired preset value, and then use Set Total
Hours or Set Drive Hours to apply the preset to the hourmeter.
Set Total Hours
OFF/ON Program this parameter On to load the preset value into the total
hourmeter. Once it has been loaded, the parameter is reset to Off
automatically.
Set Drive Hours
OFF/ON Program this parameter On to load the preset value into the drive
hourmeter. Once it has been loaded, the parameter is reset to Off
automatically.
Total Service Hours 100–5000 hours Sets the timer for the next scheduled overall maintenance.
Drive Service Hours 100–5000 hours Sets the timer for the next scheduled traction motor maintenance.
Total Disable Hours 0–500 hours Sets the total disable timer; if the programmed time expires, the Drive
Disable Speed goes into effect.
Drive Disable Hours 0–500 hours Sets the drive disable timer; if the programmed time expires, the Drive
Disable Speed goes into effect.
Drive Disable Speed 0–80 % Sets the maximum drive speed that will be in effect if either of the disable
timers expires. It applies to both M1 and M2 Max Speed.
Service Total Expired
OFF/ON When the total service timer expires, the controller automatically sets
the Service Total Expired parameter On. The parameter must then be
programmed Off to indicated the appropriate service has been performed.
Service Drive Expired
OFF/ON When the drive service timer expires, the controller automatically sets
the Service Drive Expired parameter On. The parameter must then be
programmed Off to indicated the appropriate service has been performed.
Two hourmeters (total KSI on-time and traction motor on-time) are built into
the 1230 controller. Each has a corresponding service timer and disable timer.
The service timer sets the time for periodic maintenance. When the service
time expires, the disable timer starts.

Table of Contents

Questions and Answers: