Curtis 1212 Manual
13
DRIVE MENU, cont’d
ALLOWABLE
PARAMETER RANGE DESCRIPTION
E Stop Decel 0.2–4.0 sec Sets the rate (in seconds) that is used to slow down the vehicle during
emergency reverse, i.e., when a throttle command >80% in the reverse
direction is given while the vehicle is moving forward. This gives the
operator a way to stop more quickly when unexpected conditions arise.
E Stop Pause 0.0–1.0 sec Sets a pause before reversing direction after an emergency reverse stop.
This gives the operator time to return the throttle to neutral without moving
backwards.
Soft Start 0–100 % This parameter can be used to soften the bump associated with gear
slack in the transaxle when throttle is applied from the neutral state. Larger
values provide a softer slack take-up.
Gear Soften 0–100 % This parameter is intended to soften the bump associated with gear slack
in the transaxle when throttle is released and then reapplied while the
vehicle is still moving. Larger values provide a softer slack take-up.
Creep Speed 0–10 % Creep Speed helps to prevent vehicle rollback on inclines when the brake
is released with very little throttle applied. It is activated when the throttle
request exceeds the throttle deadband threshold.
Push Max Speed 25–50 % Sets the maximum speed at which the vehicle can be pushed.
When the vehicle is powered on and in neutral, it enters the push
mode when the push button is activated. The electromagnetic brake is
released, driving is inhibited, and speed is limited to Push Max Speed.
When the vehicle is not powered on and the brake is mechanically
released to enable pushing, Push Max Speed still applies. Once sufficient
voltage is generated by the motor, speed will be limited by the controller.
Soft Stop Speed 0–30 % Sets the speed at which a gentler deceleration is initiated when the throttle
is released to neutral; larger values start the soft stop deceleration sooner.
3 — PROGRAMMABLE PARAMETERS:
Drive Parameters

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtis 1212 and is the answer not in the manual?

Curtis 1212 Specifications

General IconGeneral
BrandCurtis
Model1212
CategoryController
LanguageEnglish

Related product manuals