Type 1 Fault Codes
When Fault Code Type parameter is set to 1, the status LED uses the fault
codes listed in Table 2-1. Five single-digit codes are used: 1, 7, 8, 9, and 10.
Table 2-1 STATUS LED FAULT CODES, TYPE 1
TYPE 1 LED CODES FAULT
LED off no power or defective controller
solid on controller powered up; no faults
1
¤ BATTERY DISCONNECT FAULT ❊
UNDERVOLTAGE FAULT
7 ¤¤¤¤¤¤¤ HPD FAULT
THROTTLE FAULT
WIRING FAULT ❊
8 ¤¤¤¤¤¤¤¤ BRAKE OFF FAULT
CURRENT SENSE FAULT ❊
EE CHECKSUM FAULT †
HARDWARE FAILSAFE ❊
MAIN FAULT ❊
MAIN OFF FAULT
MAIN ON FAULT
PRECHARGE FAULT ❊
9 ¤¤¤¤¤¤¤¤¤ BRAKE ON FAULT
10 ¤¤¤¤¤¤¤¤¤¤ OVERVOLTAGE FAULT
7 — DIAGNOSTICS & TROUBLESHOOTING
❊ = Must cycle keyswitch to clear.
† = Must use programmer to clear, as follows: select Program menu,
alter data value of any parameter, cycle keyswitch.