5 — MONITOR MENU
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC
pg. 74
Monitor Menu: CONTROLLER
VARIABLE DISPLAY RANGE DESCRIPTION
Current (RMS)
Current_RMS
0x3209 0x00
0.0 – 1000.0 A
0 – 10000
RMS current of the controller, taking all three phases into account.
Modulation Depth
Modulation_Depth
0x3208 0x00
0.0 – 100.0%
0 – 1182
Percentage of available voltage being used.
Frequency
Frequency
0x3206 0x00
–500 – 500 Hz
–3000 – 3000
Controller electrical frequency.
Temperature
Controller_Temperature
0x322A 0x00
–100 – 300°C
–1000 – 3000
Controller internal temperature.
Main State
Main_State
0x3223 0x00
0 – 10
0 – 10
Main contactor state:
0 = open
1 = precharge
2 = weld check
3 = closing delay
4 = missing check
5 = closed (when Main Enable = On)
6 = delay
7 = arc check
8 = open delay
9 = fault
10 = closed (when Main Enable = Off).
EMBrake State
EMBrakeState
0x3892 0x00
0 – 4
0 – 4
EM brake state:
0 = engaged
1 = releasing
2 = released
3 = engaging
4 = engaged and vehicle stopped.
Regen
|Regen_State
|System_Flags1 [Bit 2]
0x322B 0x00
On / Off
On / Off
On when regen braking is taking place; Off when it is not.
Master Timer
Master_Timer
0x3160 0x00
0 – 429496729.5 s
O – 4294967295
The master timer is a timer of the total hours the controller is powered on
(keyswitch hours). The master timer is controlled by the OS software and
cannot be reset.
VCL Error Module
Last_VCL_Error_Module
0x3473 0x00
0 – 65535
0 – 65535
A VCL Runtime Error (fault code 68) will store additional information about
the cause of a VCL runtime error in the VCL Error Module and VCL Error
variables. The resulting non-zero values can be compared to the runtime
VCL module ID and error code denitions listed in the controller’s OS
SysInfo le, which should help pinpoint the VCL error that caused the
runtime error.
VCL Error
Last_VCL_Error
0x3472 0x00
0 – 65535
0 – 65535