Error 93: Over Voltage (DC Link)
Cause:
Drive’s internal boost circuit is reporting >400V DC on the bus.
Service:
Verify line voltage isn’t spiking.
Check the treadmill’s internal AC wiring.
Verify correct voltage controller is used with regard to power at the outlet.
Replace the Drive controller if the error continues.