Error 96: Thermal Integrator of output current
Cause:
The drive has several over-current situations that can cause this:
>200% Rated for 3 seconds (roughly 16A)
>150% Rated for 1 minute (roughly 12A)
>101% Rated for accumulated time (roughly =>8.1A)
Service:
Check drive’s cooling fan and heat sink for clogs.
Verify line voltage isn’t sagging.
Check the belt/deck for wear.
Check treadmill for physical obstructions, seized bearings, etc.
Investigate actual line current with various weight users. Determine user weight, speed and incline
when error occurred.