Error 99: Display Communication Lost Belt moving
Cause:
The drive did not see valid communication response from the display for >400ms while the belt was
moving.
Service:
Check the console cable, hub board, and hub board cable for tears or shorts, and verify all connections
are clicked-in and solid.
Check for terminal corrosion.
Check drive and display communications with the Cybex test protocol software on a laptop.
Reprogram the console or replace the display board.
Page 91 of 199