Error 142: Out of incline range (over 15% or lower than -3%)
Cause:
The Drive Controller encountered the zero switch when outside of expected limits. The display will shut
down power to the elevation motor, and show dashes for incline until the drive has made a satisfactory
calibration.
Service:
Check the 0% switch setting
Checkgearmotor wiring
Check correct voltages and frequency settings