Error 150: Out of SpeedRange (over 150hz)
Cause:
Target speed >150Hz. Console is either sending a false speed value, or the value or data transfer is
corrupt.
Service:
The display software is suspect. If this occurs, contact Cybex Customer Service immediately. The best
course of action is to upgrade the display software with the most up to date revision, either by replacing
the display board or upgrading the existing board.
Exit error log
Exit Set Up Mode by tapping the Toolbox icon, then tap the Home icon . The screen will
refresh.
Software Update 770T
Software can ONLY be installed on the model it is designed for. Do NOT install this software on other
Arc Trainers, Bikes, or Treadmills.
Tools Required
• USB stick (CP-23199)
• Phillips screwdriver
Repairs and Service
• DO NOT load zip files onto USB stick
• Load un-zipped files onto USB stick
• DO NOT remove USB stick during upload procedure
• Power must remain on during upload procedure
• DO NOT press any keys on console during upload procedure
Prepare USB stick
1. Plug USB stick into PC.
2. Delete any files on USB stick.
Verify USB stick is blank.
3.
Go to the LF World service product pages for the latest software files or contact Cybex Customer
Service at 508-533-4300 to receive via email.