8.2.2 Positioning of the user interface in conditioning and cold water systems
The user interface can be positioned only with the cable facing downwards.
Figure 5: Positions of the user interface
8.3 Rotation of the user interface
If the circulator is installed on pipes in a horizontal position, it will be necessary to rotate the interface with the
respective electronic device through 90 degrees in order to maintain the grade of IP protection and to allow
the user a more convenient interaction with the graphic interface.
Before rotating the circulator, ensure that it has been completely drained.
To rotate the EVOSTA2, EVOSTA3 circulator, proceed as follows:
1. Remove the 4 fixing screws of the circulator head.
2. Rotate the motor casing with the electronic control device through 90 degrees clockwise or
counterclockwise, as necessary.
3. Reassemble and tighten the 4 screws that fix the circulator head.
The electronic control device must always remain in vertical position!
Figure 6: Changing the position of the user interface

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DAB EVOSTA2 and is the answer not in the manual?

DAB EVOSTA2 Specifications

General IconGeneral
Power Supply230 V
Frequency50/60 Hz
Temperature Range-10°C to +110°C
Insulation classF
Maximum working pressure10 bar
Pumped liquidClean water
Max Head6.9 meters

Related product manuals