3.3 Editing Using an External Personal Computer
3-17
Description of
Code External appearance Format
function
3020
Displays
(3 digits)
In sequence from the first parameter:
1: Base color
2: Display data selection (0: Input signal/1: Output
signal/2: Variable Int)
3: Method of read (0: Binary/1: BCD)
4: Input signal to be displayed 1
:
15: Input signal to be displayed 12
16: Output signal to be displayed 1
:
27: Output signal to be displayed 12
28: Variable integer to be displayed
29: “0”
No descriptions are required for all parameters from
30 onward.
Left
side
3021
Right
side
13021
Displays
(6 digits)
3021 (display 6 digits, left side)
In sequence from the first parameter:
1: Base color
2: Display data selection (0: Input signal/1: Output
signal/2: Variable Int)
3: Method of read (0: Binary/1: BCD)
4: Input signal to be displayed 1
:
27: Input signal to be displayed 24
28: “0”
No descriptions are required for all parameters from
29 onward.
13021 (display 6 digits, right side)
In sequence from the first parameter:
1: Output signal to be displayed 1
:
24: Output signal to be displayed 24
25: Variable integer to be displayed
"0" is set for all subsequent parameters starting with
parameter 26.
3030
Input 3digits
In sequence from the first parameter:
1: Base color
2: Output data format (0: Binary/1: BCD)
3: Output signal 1
:
14: Output signal 12
15: Operation inhibit (0: Enabled / 1: Disabled)
16: “0”
No descriptions are required for all parameters from
17 onward.
Left
side
3031
Right
side
13031
Input 6digits
3031 (input 6 digits, left side)
In sequence from the first parameter:
1: Base color
2: Output data format (0: Binary/1: BCD)
3: Output signal 1
:
26: Output signal 24
27: Operation inhibit (0: Enabled / 1: Disabled)
28: “0”
No descriptions are required for all parameters from
29 onward.
13031 (input 6 digits, right side)
No setting.
All parameters are set to 0.