10 | Configuration
Installer reference guide
119
EPGA11~16DAV3(7) + EAVZ16S18+23DA6V(7)+9W
Daikin Altherma 3 H F
4P556075-1A – 2021.09
INFORMATION
The setting [F‑0B] is only valid when there is a thermostat or external room
thermostat request setting (NOT in case of leaving water temperature setting).
10.5.4 Additional zone
Setpoint screen
Control the leaving water temperature for the additional zone via setpoint screen
[3] Additional zone.
See "10.3.5Setpoint screen"[495].
Schedule
Indicates if the desired leaving water temperature is according to a schedule.
See "10.5.3Main zone"[4109].
# Code Description
[3.1] N/A Schedule:
▪ No
▪ Yes
Heating schedule
Define a heating temperature schedule for the additional zone via [3.2] Heating
schedule.
See "10.3.7Schedule screen: Example"[496].
Cooling schedule
Define a cooling temperature schedule for the additional zone via [3.3] Cooling
schedule.
See "10.3.7Schedule screen: Example"[496].
Setpoint mode
The setpoint mode of the additional zone can be independently set from the
setpoint mode of the main zone.
See "Setpoint mode"[4110].
# Code Description
[3.4] N/A Setpoint mode:
▪ Fixed
▪ WD heating, fixed cooling
▪ Weather dependent
Heating WD curve
Set weather-dependent heating for the additional zone (if [3.4]=1 or 2):