10 | Configuration
Installer reference guide
132
EPGA11~16DAV3(7) + EAVZ16S18+23DA6V(7)+9W
Daikin Altherma 3 H F
4P556075-1A – 2021.09
# Code Description
[5.4] [6-0C] Reheat setpoint:
30°C~min(50,[6‑0E])°C
Schedule
You can set the tank temperature schedule using the schedule screen. For more
information about this screen, see "10.3.7Schedule screen: Example"[496].
Heat up mode
The domestic hot water can be prepared in 3 different ways. They differ from each
other by the way the desired tank temperature is set and how the unit acts upon it.
# Code Description
[5.6] [6-0D] Heat up mode:
0: Reheat only: Only reheat operation is
allowed.
1: Schedule + reheat: The domestic hot
water tank is heated according to a schedule
and between the scheduled heat up cycles,
reheat operation is allowed.
2: Schedule only: The domestic hot water
tank can ONLY be heated according to a
schedule.
See the operation manual for more details.
10.5.7 User settings
Language
# Code Description
[7.1] N/A Language
Time/date
# Code Description
[7.2] N/A Set the local time and date
INFORMATION
By default, daylight savings time is enabled and clock format is set to 24 hours. If you
want to change these settings, you can do this in the menu structure (User
settings > Time/date) once the unit is initialised.
Holiday
About holiday mode
During your holiday, you can use the holiday mode to deviate from your normal
schedules without having to change them. While holiday mode is active, space
heating operation and domestic hot water operation will be turned off. Room frost
protection and anti-legionella operation will remain active.