6 | Application guidelines
Installer reference guide
36
EPGA11~16DAV3(7) + EAVZ16S18+23DA6V(7)+9W
Daikin Altherma 3 H F
4P556075-1A – 2021.09
6.3.6 DHW pump for disinfection
Setup
c
a
b
d f
e g
h
i
a Indoor unit
b DHW tank
c DHW pump (field supply)
d Heater element (field supply)
e Non‑return valve (field supply)
f Shower (field supply)
g Cold water
h Domestic hot water OUT
i Recirculation connection
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see "9.2.5To connect the domestic hot water
pump"[483].
If the applicable legislation requires a higher temperature than the maximum
tank setpoint during disinfection (see [2-03] in the field settings table), you can
connect a DHW pump and heater element as shown above.
If applicable legislation requires disinfection of the water piping until the tapping
point, you can connect a DHW pump and heater element (if needed) as shown
above.
To ensure a complete disinfection, you have to open the tapping point.
WARNING
When opening the tapping point, the water temperature can be up to 55°C.
Configuration
The indoor unit can control DHW pump operation. For more information, see
"10Configuration"[487].
6.4 Setting up the energy metering
Via the user interface, you can read out the following energy data:
- Produced heat
- Consumed energy
You can read out the energy data:
- For space heating
- For domestic hot water production
You can read out the energy data:
- Per month
- Per year
INFORMATION
The calculated produced heat and consumed energy are an estimation, the accuracy
cannot be guaranteed.