16 | Technical data
Installer reference guide
201
EPGA11~16DAV3(7) + EAVZ16S18+23DA6V(7)+9W
Daikin Altherma 3 H F
4P556075-1A – 2021.09
16.6 ESP curve: Indoor unit
Note: A flow error will occur when the minimum water flow rate is not reached.
4D120999
B (l/min)
0
40
60
80
100
30
50
70
90
110
20
0
5 10 15 20 25 30 35 40 45 50 55 60 65
10
120
C
A (kPa)
A External static pressure in the space heating circuit
B Water flow rate through the unit in the space heating circuit
C Operation range
Additional/direct zone
Main/mixed zone
Dashed lines: Operation area is extended to lower flow rates only in case the unit
operates with heat pump only. (Not in startup, no backup heater operation, no
defrost operation.)
Notes:
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specifications.
Make sure water quality complies with EU directive 2020/2184.