4 Unit installation
Installation manual
6
EBSH/X(B)11+16P50D
Daikin Altherma 3 R ECHO
4P759878-1 – 2024.01
WARNING
Do NOT pierce or burn refrigerant cycle parts.
Do NOT use means to accelerate the defrosting
process or to clean the equipment, other than those
recommended by the manufacturer.
Be aware that R32 refrigerant does NOT contain an
odour.
WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (example: open flames, an
operating gas appliance or an operating electric heater)
and have a room size as specified below.
NOTICE
Do NOT re-use joints and copper gaskets which have
been used already.
Joints made in the installation between parts of the
refrigerant system shall be accessible for maintenance
purposes.
WARNING
Make sure installation, servicing, maintenance and repair
comply with instructions from Daikin and with applicable
legislation (for example national gas regulation) and are
executed ONLY by authorised persons.
NOTICE
The pipework shall be securely mounted and guarded
protected from physical damage.
Keep the pipework installation to a minimum.