7 Installation
Installer reference guide
44
ERGA04~08DAV3(A) + EHBH/X04+08DA
Daikin Altherma – Low temperature split
4P496758-1 – 2017.12
Backup
heater type
Backup
heater
capacity
Power
supply
Maximum
running
current
Z
max
*6V 2kW 1N~230V 9A
4kW 1N~230V 17A
(a)(b)
0.22Ω
6kW 1N~230V 26A
(a)(b)
0.22Ω
2kW 3~230V 5A
4kW 3~230V 10A
6kW 3~230V 15A
*9W 3kW 3N~400V 4A
6kW 3N~400V 9A
9kW 3N~400V 13A
(a) Equipment complying with EN/IEC61000-3-12 (European/
International Technical Standard setting the limits for
harmonic currents produced by equipment connected to
public low-voltage systems with input current >16A and
≤75A per phase.).
(b) This equipment complies with EN/IEC61000‑3‑11
(European/International Technical Standard setting the
limits for voltage changes, voltage fluctuations and flicker in
public low-voltage supply systems for equipment with rated
current ≤75A) provided that the system impedance Z
sys
is
less than or equal to Z
max
at the interface point between the
user's supply and the public system. It is the responsibility
of the installer or user of the equipment to ensure, by
consultation with the distribution network operator if
necessary, that the equipment is connected only to a
supply with a system impedance Z
sys
less than or equal to
Z
max
.
Connect the backup heater power supply as follows:
a
b
X6M
F1B
Q1DI
a Factory-mounted cable connected to the backup heater
contactor inside the switch box (K5M for *6V and *9W
models)
b Field wiring (see table below)
Model (power
supply)
Connections to backup heater power
supply
*6V (1N~230V)
1N~, 50 Hz
230 V AC
SWB
4
3
6
5
2
1
K5M
14
13
Q1DI
1
2
3
4
5
6
7
8
F1B
II I I
NL
X6M
*6V (3~230V)
SWB
3~, 50 Hz
230 V AC
4
3
6
5
2
1
K5M
14
13
1
2
3
4
5
6
7
8
F1B
II I I
Q1DI
L1 L2 L3
X6M
*9W (3N~400V)
3N~, 50 Hz
400 V AC
SWB
Q1DI
L1 L2 L3 N
1
2
3
4
5
6
7
8
F1B
II I I
X6M
2
1
K5M
4
3
6
5
14
13
F1B Overcurrent fuse (field supply). Recommended fuse for *6V
and *9W models: 4‑pole; 20A; curve 400V; tripping class
C.
K1M Contactor (in the switch box)
K5M Safety contactor (in the switch box)
Q1DI Earth leakage circuit breaker (field supply)
SWB Switch box
X6M Terminal (field supply)
Final English - Tanslations in progress