EasyManua.ls Logo

Daikin EHBX08DA9W - Wiring Diagram: Indoor Unit

Daikin EHBX08DA9W
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 Technical data
Installer reference guide
95
ERGA04~08DAV3(A) + EHBH/X04+08DA
Daikin Altherma – Low temperature split
4P496758-1 – 2017.12
Electrical connection diagram
For more details, please check the unit wiring.
2x0.75
(F1B)
Q*L
3Gx2.5
230 V
A8P: X801M: 1-5
A8P: X801M: 2-5
A8P: X801M: 3-5
A8P: X801M: 4-5
X1M: 1-2-3
X2M: 5-6
X5M: 9-10
X9A (PCB A1P)
SPST:
X2M: 12-13-14a
A4P: Y1-YC
X2M: 7-9
A4P: X1-X2
X5M: 11-12
X2M: 1-2
X5M: 7-8
X5M: 5-6
X5M: 3-4
A4P: Y2-YC
X2M: 7-9
A4P: Y3-YC
X2M: 7-9
230 V
230 V
230 V
230 V
230 V
A3P: X11M: 5-6
4D111879C
A15P: X1M: H-C-com
X2M: L-N
A2P: X1M: 1-3
A2P: X1M: C-com-H
R2T
X2M: 7-9
(F2B)
X1M: 1-2-3
X5M
X6M
3
3
3
1
1
2
2
230 V
- In case of signal cable: keep minimum distance to power cables >5 cm
- Available heaters depending on model: see combination table
Notes:
X1M: L-N-earth
3 core
normal kWh rate power supply for indoor unit: 230 V
Field supply
booster heater power supply (3 kW): 400 V or 230 V + earth
BSK: A3P: 1-2 solar interlock
Cooling/heating
On/OFF output
Circulation pump
for DHW
Ext. heat source (e.g. boiler)
Alarm indication
Only for *KSR3PA option
Only for KRCS01-1 or EKRSCA1
Electricity meter
pulse input 2
Electricity meter
pulse input 1
external thermistor
(indoor or outdoor)
M2S
for cooling mode
2-way valve
External sensor
(floor or ambient)
signal
Only for EKRUDAS
Only for *KRTETS
2 core
(3m included)
Only for
(heat pump convector)
Only for *KRTW
(wired room thermostat)
Only for *KRTR
(wireless room thermostat)
A13P: P1-P2 LAN adapter
A14P: P1-P2 user interface
Optional parts
Optional parts
External room thermostat / Heat pump convector
(main and/or additional zone)
5 core for C/H operation
4 core for H only operation
3 core for C/H operation
2 core for H only operation
2 core
2 core
communication
2x0.75
2 core
2 core
signal
2 core
signal
2 core
2 core
communication
2x0.75
2 core
2 core
2 core
signal
2 core
2 core
Only for *KRP1HB*
Changeover to
ext. heat source output
Alarm output
Solar input
Cooling/heating
On/OFF output
NO valve: X2M: 21-28
NC valve: X2M: 21-29
main: X2M: 30-35
add: X2M: 30-35a
main: X2M: 30-31-34-35
add: X2M: 30-31-34a-35a
main: X2M: 30-34-35
add: X2M: 30-34a-35a
or L1/L2/L3-N + earth
or L1-L2 + earth
X8M: L-N + earth
or L1-L2-L3-N + earth
or L-N + earth
X6M: L1-L2-L3 + earth
Only for *KHWSU*V3
X7M: 1-2-earth
Only for *KRP1AHTA
2 core
2 core
3 core
signal
230 V
3 core
2 core
2 core
2 core
2 core
Power limitation
demand input 4
Power limitation
demand input 3
Power limitation
demand input 2
Power limitation
demand input 1
Field supply
M3S (when *KHW is installed)
selection domestic hot water-floor heating
3-way valve
R5T - thermistor
water temperature
Booster heater
clixon
2-way valve
Domestic hot
water tank
3 core
Optional parts (*KHW*)
5 or 4 or 3
core
backup heater power supply: 400 V or 230 V + earth
Safety thermostat
Preferential kWh rate power supply contact
230 V + earth
Only for preferential kWh rate power supply installation
unit preferential kWh rate power supply:
2 core
3 core
3 core
3 core
unit power supply: 230 V + earth
Only for normal power supply installation
Field supply
Indoor unit
Standard part
Outdoor unit
Power supply
signal
signal
signal
signal
signal
signal
signal
signal
Final English - Tanslations in progress

Table of Contents

Other manuals for Daikin EHBX08DA9W

Related product manuals